On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry
文献信息
Gustav Liljegren, Niklas Forsgard, Camilla Zettersten, Jean Pettersson, Malin Svedberg, Merja Herranen, Leif Nyholm
Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 µM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.
相关文献
Correction: α-Diimine nickel complexes bearing axially bulky terphenyl and equatorially bulky dibenzobarrelene groups: synthesis, characterization and olefin polymerization studies
Bo Dong, Qi Yang
DOI: 10.1039/D1PY90152D
The role of the electrostatic potential, electric field and electric field gradient on the acidity of AFI and CHA zeotypes
Dewi W. Lewis
DOI: 10.1039/A907464C
Numbers and densities of states and partition functions from an efficient approach to phase space integration
Stefan Schmatz
DOI: 10.1039/B009788H
Absorption and electroabsorption spectra of [(NH3)5Ru–pyrazine]2+ and [(NH3)5Ru–pyrazine–H]3+ by a vibronic model Hamiltonian
Alessandro Ferretti, Roberto Improta, Alessandro Lami, Giovanni Villani
DOI: 10.1039/B008278N
Post-polymerization ‘click’ end-capping of polyglyoxylate self-immolative polymers
Peter G. Maschmeyer, Xiaoli Liang, Allison Hung, Oksana Ahmadzai, Annmaree L. Kenny, Yuan C. Luong, Timothy N. Forder, Haoxiang Zeng
DOI: 10.1039/D1PY01169C
Unimolecular decay of the Cl−···CH3Cl complex: Influence of symmetry breaking
S. Schmatz, P. Botschwina
DOI: 10.1039/B009879P
On the role of nonergodicity and slow IVR in unimolecular reaction rate theory—A review and a view
DOI: 10.1039/B009963P
您可能还喜欢
什么是5-Fluoro-4-iodo-2-methylaniline(CAS号:307306-08-7)?
5-氟-4-碘-2-甲氨基苯属于芳香族化合物,其分子式为C8H7FN2I。该化合物具有一定的反应活性,在有机合成和药物化学领域有一定的应用。
4-氟-3-硝基三氟甲苯(CAS号:367-86-2)通常如何合成?
4-氟-3-硝基三氟甲苯通常通过将三氟甲基苯在酸性条件下催化氧化为三氟甲基硝基苯,然后进行氟化反应得到目标化合物。该过程需要使用催化剂,如三氟乙酸,反应产率较高...
6-氯-9-(2,3,5-三苯甲酰氧基-2-C-甲基-beta-D-呋喃核糖基)-9H-嘌呤(CAS号:205171-05-7)的物理化学性质是什么?
该化合物为白色至类白色晶体,分子量约为1046.95。它在水中几乎不溶,在有机溶剂如乙腈和甲醇中具有一定的溶解性。该化合物具有良好的化学稳定性和生物活性。
如何储存6-氟喹啉-4-羧酸(CAS号:220844-73-5)?
6-氟喹啉-4-羧酸应储存在阴凉、干燥、通风良好的地方,避免阳光直射。储存在密闭容器中,避免与空气中的水分接触。储存温度应控制在室温以下,避免高温。
(2S,2'S,3S,3'S)-3,3'-di-tert-butyl-4,4'-bis(2,6-dimethoxyphenyl)-2,2',3,3'-tetrahydro-2,2'-bibenzo[d][1,3]oxaphosphole(CAS号:1435940-21-8)通常如何合成?
该化合物通常通过芳香族化合物的亲核取代反应合成,首先将2,6-二甲氧基苯基引入到双环结构中,然后通过特定条件下的还原或氧化反应引入二叔丁基。反应过程中使用了钯作...
如何储存KY02111(CAS号:1118807-13-8)?
KY02111应储存于阴凉、干燥、通风良好的地方,避免阳光直射和高温环境。应使用合适的密闭容器储存,并确保容器密封良好,防止水分和潮气进入。在储存期间,应注意检...
如何储存4-(4-氯苯氧基)丁酸乙酯(CAS号:59227-79-1)?
4-(4-氯苯氧基)丁酸乙酯应储存在阴凉、干燥、通风良好的地方,远离火源和热源。避免阳光直射,防止容器破裂导致泄漏。储存时应保持容器密封,避免与空气中的水蒸气接...
4-庚基苯乙酮(CAS号:37593-03-6)安全吗?
4-庚基苯乙酮相对安全,但在使用和储存时仍需注意。应避免吸入其蒸气,避免皮肤接触,使用时需佩戴防护眼镜和手套。储存时应远离火源和热源,保持容器密封,放置于阴凉、...
什么是乙基2-氨基-4-(3-溴苯基)噻吩-3-羧酸乙酯(CAS号:438218-48-5)?
乙基2-氨基-4-(3-溴苯基)噻吩-3-羧酸乙酯是一种有机化合物,分子式为C16H12BrN2O2S。它是一种含有噻吩环、氨基、溴苯基和羧酸酯结构的化合物。这...
什么是(9ci)-2-氨基-6-甲基-苯甲酰胺(CAS号:1885-31-0)?
(9ci)-2-氨基-6-甲基-苯甲酰胺是一种化学化合物,其英文名称为2-Amino-6-methylbenzamide,CAS号为1885-31-0。该化合物...
来源期刊
Analyst

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.













![N-[(E)-Phenylmethylene]benzenesulfonamide structure N-[(E)-Phenylmethylene]benzenesulfonamide structure](https://cnstatic.chemtradehub.com/structs/139/13909-34-7-8167.webp)
