Equivalency calculation of unknown enzyme inhibitors in situ the adsorbent of effect-directed autograms
文献信息
Ebrahim Azadniya, Gertrud E. Morlock
Reliable biochemical quantification of the enzymatically produced signals of enzyme inhibitors has recently been achieved in situ an assay-containing chromatographic bed, i.e. the adsorbent of an effect-directed autogram. As most of the enzyme inhibitors discovered in a complex sample are unknown or unidentified, external standard calibration cannot be performed, and their inhibition potency needs to be estimated by alternative means. Thus, herein, two different modes of equivalency calculation, referring to a potent inhibitor that was either applied or developed, were investigated, validated and compared, exemplarily for acetyl- and butyrylcholinesterase (AChE/BChE) inhibition zones in the Peganum harmala (P. h.) seed extract. Moreover, three potent inhibitors, i.e. physostigmine (PHY), rivastigmine and piperine, were considered for equivalency calculation. With regard to their hRF value, band shape and inhibition brightness against the plate background, the properties of PHY were most similar to those of the unidentified inhibitors in the P. h. seed extract, and thus, it was selected as a reference. The HPTLC-AChE assay with 1-naphthyl acetate as a substrate and Fast Blue B salt as a chromogenic reagent was suitable to reveal the potential differences between the two modes of equivalency calculation due to its low limits of detection. Quantification was studied via PHY zones that were applied versus developed on a high-performance thin-layer chromatography (HPTLC) plate. Both intraday precision and reproducibility showed the same trend, i.e. the equivalency calculation via the developed PHY bands was more repeatable than that via the applied PHY bands. The steeper slope of the calibration curve of the developed PHY bands offered a more sensitive quantification. The resulting equivalent inhibition of the ChE inhibitors in 1 μg per band of P. h. seed extract showed a bias of ca. 30% when calculated via the applied versus developed PHY bands, whereby the total AChE-to-BChE inhibition ratio (ca. 2.4) of the ChE inhibitors in 1 μg per band of P. h. seed extract remained almost the same. As a result, the enzyme inhibition equivalency calculated via the developed reference bands was more reliable and sensitive than that calculated via the applied reference bands. When a faster procedure (applied band pattern) is selected for routine equivalency calculation as a compromise, a potential bias has to be taken into account.
相关文献
Computational investigation of a promising Si–Cu anode material
Ksenia A. Ivanichkina
DOI: 10.1039/C9CP01571J
Judging the feasibility of TiO2 as photocatalyst for chemical energy conversion by quantitative reactivity determinants
Martin Dilla, Nikolaos G. Moustakas, Ahmet E. Becerikli, Tim Peppel, Armin Springer, Jennifer Strunk, Simon Ristig
DOI: 10.1039/C9CP00981G
Organic salts utilising the hexamethylguanidinium cation: the influence of the anion on the structural, physical and thermal properties
Ruhamah Yunis, Anthony F. Hollenkamp, Craig Forsyth, Cara M. Doherty, Danah Al-Masri, Jennifer M. Pringle
DOI: 10.1039/C9CP01740B
Diverging surface reactions at TiO2- or ZnO-based photoanodes in dye-sensitized solar cells
Raffael Ruess, Sabina Scarabino, Andreas Ringleb, Kazuteru Nonomura, Nick Vlachopoulos, Anders Hagfeldt, Gunther Wittstock, Derck Schlettwein
DOI: 10.1039/C9CP01215J
Revising the common understanding of metamagnetism in the molecule-based bisdithiazolyl BDTMe compound
Mercè Deumal
DOI: 10.1039/C9CP00467J
Understanding the affinity of bis-exTTF macrocyclic receptors towards fullerene recognition
Joaquín Calbo, Alberto de Juan, Juan Aragó, Julia Villalva, Emilio M. Pérez, Enrique Ortí
DOI: 10.1039/C9CP01735F
Triplet–triplet annihilation based photon up-conversion in hybrid molecule–semiconductor nanocrystal systems
Alessandra Ronchi, Paolo Brazzo, Mauro Sassi, Luca Beverina, Jacopo Pedrini, Francesco Meinardi, Angelo Monguzzi
DOI: 10.1039/C9CP01692A
Pretransitional behavior of viscoelastic parameters at the nematic to twist-bend nematic phase transition in flexible n-mers
Zeinab Parsouzi, Mojtaba Rajabi, Rony Saha, Prabesh Gyawali, Alan R. Baldwin, Chris Welch, Georg H. Mehl, J. T. Gleeson, Samuel Sprunt
DOI: 10.1039/C9CP00984A
Interface-tuned selective reductive coupling of nitroarenes to aromatic azo and azoxy: a first-principles-based microkinetics study
Lidong Zhang, Zheng-Jiang Shao, Xiao-Ming Cao
DOI: 10.1039/C9CP01795J
Single Pt atom supported on penta-graphene as an efficient catalyst for CO oxidation
Ranganathan Krishnan, Shiuan-Yau Wu, Hsin-Tsung Chen
DOI: 10.1039/C9CP02306B
您可能还喜欢
硅烷偶联剂ZQ-172(CAS号:1067-53-4)的主要用途是什么?
硅烷偶联剂ZQ-172主要用于增强无机填料与有机高分子材料之间的相容性,常见于橡胶、塑料、涂料和胶黏剂等复合体系中。其硅氧烷基团可与玻璃纤维、二氧化硅等无机物表...
如何处理含有6-(2,4-二甲氧基苯基)-2-吡啶甲醇(CAS号:887981-31-9)的废料?
对于含有该化合物的废料,首先应收集并分类存放,避免与其它化学品混合。在处理前,需进行必要的检测,确定其含量和性质。随后,可以采用化学氧化、生物降解或物理吸附等方...
甲砜霉素甘氨酸酯盐酸盐(CAS号:2611-61-2)的物理化学性质是什么?
该化合物为白色或类白色结晶性粉末,不溶于水,溶于乙醇和氯仿。分子量为403.03 g/mol。它具有手性,含有三个手性中心,分别为2S,3R构型。该化合物在酸性...
如何储存反式-环丙烷-1,2-二胺双盐酸盐(CAS号:3187-76-6)?
反式-环丙烷-1,2-二胺双盐酸盐应存放在阴凉、干燥且通风良好的地方,避免阳光直射。储存容器应密封,以防挥发和受潮。同时,应远离火源和热源,确保储存环境温度不超...
什么是吩嗪硫酸甲酯(CAS号:299-11-6)?
吩嗪硫酸甲酯是一种有机化合物,化学结构由吩嗪环与甲酯基团构成,分子式为C10H9N2SO4。其为吩嗪类衍生物,具有典型的芳香环结构和酯基官能团,常作为氧化剂或染...
N1-异丙基二乙烯三胺(CAS号:207399-20-0)的市场或研究趋势如何?
随着绿色化学和环保意识的提高,N1-异丙基二乙烯三胺的研究趋势正向低毒、环保的方向发展。市场趋势方面,由于其在功能性材料、药物合成等领域的需求,预计其市场需求将...
4,4-Dimethyl-5,6-dihydro-4H-cyclopenta[d][1,3]thiazol-2-amine(CAS号:1182284-47-4)应用于哪些行业?
该化合物在医药、聚合物、传感器和半导体领域有潜在的应用。在医药领域,作为一种新型的噻唑类化合物,它可能具有抗炎、抗病毒等生物活性。在聚合物领域,该化合物可用作增...
处理5-(PYRIDIN-4-YL)-OXAZOL-2-YLAMINE(CAS号:1014629-83-4)时应注意哪些实验室安全事项?
在处理5-(吡啶-4-基)-2-氧代-1-氧杂环己烷-3-胺时,应佩戴防护眼镜、手套和防护服。实验应在通风橱中进行,以避免吸入有害气体。如果发生泄露,应立即用大...
什么是伊托必利N-氧化物(CAS号:141996-98-7)?
伊托必利N-氧化物是一种化学化合物,其分子结构是伊托必利的N位进行氧化处理后的产物。它具有一定的生物活性,主要用于药物研究和开发。
氟氯烟酸(CAS号:82671-06-5)安全吗?
氟氯烟酸属于有机氯化物,具有一定的毒性,需谨慎处理。在操作过程中,应佩戴防护手套、护目镜和实验服,避免吸入其粉尘或蒸汽。接触皮肤或眼睛可能导致刺激,应采取适当的...
来源期刊
Analytical Methods

Analytical Methods welcomes early applications of new analytical and bioanalytical methods and technology demonstrating the potential for societal impact. We require that methods and technology reported in the journal are sufficiently innovative, robust, accurate, and compared to other available methods for the intended application. Developments with interdisciplinary approaches are particularly welcome. Systems should be proven with suitably complex and analytically challenging samples. We encourage developments within, but not limited to, the following technologies and applications: global health, point-of-care and molecular diagnostics biosensors and bioengineering drug development and pharmaceutical analysis applied microfluidics and nanotechnology omics studies, such as proteomics, metabolomics or glycomics environmental, agricultural and food science neuroscience biochemical and clinical analysis forensic analysis industrial process and method development














